Sommer Cable 234 - SC-BINARY 234 AES/EBU MKII - AES/EBU & DMX-Cable (1 m / 2 x 0,34 qmm / 6,4mm / black )

Article number: 11004442
1.99
VAT included Plus shipping costs  (from 0.00 )
3% discount: 1.93 For payment by cash in advance (bank transfer) or pickup on the spot
Sold out
Storage alert

Highlights / Advantages

    AES/EBU- and DMX-conformant, highly flexible
    Very good shielding through the use of copper spiral shielding and a fleece vaporized with aluminum
    Extremely robust with an especially strong jacket
    Only a little more expensive than a standard microphone cable


Properties

 
    Analog cables are used to transmit low frequency audio signals and to connect microphones, speakers and many other audio components.

    Primarily digital signals can be transmitted with this cable in an AES/EBU-, S/P-DIF- and DMX-format. They are stated with the respectively required surge impedance of 50, 75 or 110 ?. Please observe the surge impedance required for you peripherals, as stated in our data sheets. Almost all of our digital cables can also be used as a high quality analog cable and to connect scanners, mixing boards, HiFi-components and a number of other studio units

    In case of fire this cable will not develop any gases that are poisonous to humans, e.g. chloride. This is often a requirement in public buildings. But careful! A halogen-free cable is flammable and normally a flame-resistant effect, known as FRNC (halogen-free and flame-resistant), is required.

Low in fumes
If cables or wiring with insulation or jackets (e.g. made of PVC) containing chlorine burn, dense black fumes will be the result. Halogen-free cables or wiring only develop approx. a tenth of the fume density when compared to PVC-cables or wiring – they are thus considered to be low in fumes.

    These cables comply with the generally valid fire protection guidelines. They are halogen-free and flame-resistant. This guideline is classified.

EXPLANATION of testing procedures according to VDE 0472, Part 804:
FRNC Test Type A

A cable sample measuring 60 cm in length is vertically suspended in the center of a metal box (height 1200 mm x width 300 mm x depth 400 mm). A gas burner with a de? ned ? ame is ? xed, so that its axis is tilted by 45° in reference to the vertical. The ? ame hits the cable sample about 100 mm from the lower end. The ? ame hits until the conductor or the top most metal shielding emerges, but no longer than 20 seconds. The test is successful if the test sample did not burn or if the ? ame that resulted extinguishes itself and the damage caused by the heat of the ? ame did not reach the upper end of the test sample.

FRNC Test Type B

A cable sample measuring 60 cm in length is vertically suspended in the center of the metal box (height 1200 mm x width 300 mm x depth 400 mm). A gas burner with a de? ned ? ame is ? xed, so that its axis is tilted by 45° in reference to the vertical. The ? ame hits the cable sample about 100 mm from the lower end for about 1 – 2 minutes, depending on the weight of the sample. The test is successful if the test sample did not burn or if the ? ame that resulted extinguishes itself and the damage caused by the heat of the ? ame did not reach the upper end of the test sample.

FRNC test type C

Cable samples, each measuring 360 cm in length, are fastened side by side to a ladder-like test rack. This test rack is inserted vertically into a kiln, at a distance of 150 mm to the back of the kiln. The cable samples are reached by the ? ame at a height of approx. 60 cm, at a temperature of approx. 800 °C, by a burner of approx. 250 mm in width. The exposure time is 20 minutes. The test is successful if the ? ame that resulted extinguishes itself and the damage caused by the heat of the ? ame did not reach the upper end of the test sample.

    SOMMER CABLE mostly uses oxygen-free (OFC) or low-oxygen copper. For your information: Copper has a specific resistance of 0.0178 ? per meter, at a diameter of 1 mm². The purer the metal, the smoother it is (high bending cycles!) and the more consistent this value will remain over the years.

    The Pur Master Blend has a jacket mixture on a polyurethane basis, especially developed for SOMMER CABLE. The jacket on the PMB is resistant to notching and cold temperatures (–40 °C) and free of adhesion with a surface that is easy to clean. PMB offers the toughness and temperature resistance of PUR and the ? exibility of PVC. PMB is not halogen-free or ? ame-retardant.

    A granular mix on a PVC-basis, also exclusively developed for SOMMER CABLE. S-PVC is a super soft PVC with the “feeling“ and ? exibility of a soft rubber hose cable, but with signi? cantly more resistance to notching and cold temperatures than most standard PVC-jackets. While most jacket mixtures already start tearing during mobile application of –10 °C, the S-PVC withstands temperatures of –30 °C.



Description of Article:

To swing with your girlfriend...

like Tarzan in the jungle. With this cable you can do just that: It can take a lot of tugging, bending, and rough wear and tear. This is important when it is installed on light traverses with sharp edges. The BINARY 234 is an outstanding cable for the transmission of digital signals, format data 110 Ohm AES/EBU and DMX. It has 100 % shielding made of an aluminum-vaporized fleece and copper spiral shielding and provides very good protection against electrical and magnetic interference. This cable ensures faultless data transfer over distances of up to 100 meters. With the BINARY 234 you are on the safe side. The PUR-version is longitudinal water-tight up to a water pressure of 20 bar, i.e. water will not penetrate.

Also available in the halogen-free FRNC-version.



Application

    Networking of scanners, lighting units, digital mixing boards, etc.
    For indoor and outdoor installation
    Connection of digital audio amplifiers, DAT-recorders, etc.


 
    Cables for application especially on the stage, for open air festivals, or live events. These cables are easy to wind, simple to handle and will not knot, by using in correct way, so you can't trip when being laid out on stage. They are ideal for the professional and occasional musician.

    Cables for mobile application distinguish themselves through the flexible PVC jacket, a fine-stranded wire construction, high bending cycles, and a low bending radius. They are easy to wind and suitable for outdoor application. For extreme outdoor applications (transmission vehicles, transmission of sporting events, etc.) we recommend the version with a PUR or TPE-jacket. This jacket used on SOMMER CABLEs is extremely resistant to notching, is halogen-free, and also resistant to heat.

    These cables are optimized for sound. The special stranding or wire stranding along with perfect shielding will provide enduring listening pleasure and perfect transmission. They are used in the studio setting, in broadcasting, and in transmission vehicles.

    Cables for installation are in the first place designed for longevity and safe transmission, especially for ELA-technology. They can be wired inside buildings over long distances, but also inside audio units (amplifiers, speakers, etc.) or control cabinets. If you have special fire protection requirements, please observe the halogen-free/ PUR and FRNC symbols.

    These cables can be used to transmit and control 100 V technology. Basically almost all LF- and speaker cables in our program are suitable for use in ELA-technology. We use high quality materials for the insulation, such as PE, SPVC, PUR, Hytrel, and PP. The test voltage for our LF-cables is 1200 V, the operating voltage 300 V. The main problem in ELA-technology are the long distances to be covered. The user has to calculate them.



Technische Daten / Technical Data

234 - SC-BINARY 234 AES/EBU MKII
Aufbau / Construction: (2LI2Y0,34mm2)(ST)DY
Cu-Litze pro Ader / Copper strand per conductor: 19 x 0,15 mm
Innen-Leiter / Inner conductor: 2 x 0,34 mm2 (AWG 22)
Material Litzen / Material Leads: OFC - sauerstofffreies Kupfer / Oxygen Free Copper
Kapazität Ader/Ader bei 1 m / Capacitance of core at 1 m: 63 pF
Leiterwiderstand bei 1 km / Conductor resistance at 1 km: < 53 Ohm
Isolationswiderstand bei 1 km / Insulation Resistance at 1 km: > 1 GOhm
Material Mantel (Isolation) / Mantle material (insulation): PVC
Mantel-Durchmesser / Sheath diameter Ø: 6,4 mm
Temperaturbereich min.-max. / Temperature range min-max: -25 °C → +70 °C
Brandlast je m / Fire load per m: 0,17 kWh
Gewicht pro 1 m / Weight per 1 m: 50 g
Farbe / Color: schwarz / black
Hersteller-Artikel-Nr. / Manufacturer Item no.: 520-0051
 
 


Note

This article is sold by the meter thus the price refers to 1 meter of cable. If you need more than one meter you need to raise the amount accordingly. For example 2 items equal 2 meters of cable, 3 items equal 3 meters and so forth.

These cables are not pre-assembled which means they are delivered without connectors and such.



Scope of Delivery:

  • 1 x 1m AES/EBU & DMX-Cable


Klangvilla in Leipzig
Your advantages

We help you
Mon. - Fri. from 8.00 am - 05.00 pm
Also by email
Support within 24 hours (Mon. - Fri.)
Certified shop
Safe shopping
SSL Data Protection Security